underfloor heating

Overview




   DESCRIPTION

ECOFLOOR electric underfloor heating mats are made of a heating cable attached to a fibreglass mesh scrim. The mat can simply be rolled out onto the floor, making installation quick and easy. The mats come complete with double sided tape on the underside so they can easily be fixed to any clean surface. ECOFLOOR Underfloor Heating Mats have a twin conductor cable, with a single 3m “cold tail” connection. Our electric underfloor heating mats are vailable in two standard power ratings: 150 Watt mats for internal applications including kitchens and bathrooms and 200 Watt mats for conservatory use or areas where high heat losses can occur.

FEATURES



Approved to EN60335-2-96 as required by the 17th Edition Wiring Regulations (BS7671:2008)

Two heat outputs - 150W/m2 and 200W/m2

Quick installation - Simply roll out the electric underfloor heating mat & fix
to the floor

Suitable for tile, stone, slate and marble floor finishes 

Continuous metallic earth screen to ensure electrical safety 

Low build height - Minimal floor height build up 

Suitable for use in wet areas 

EMC Safe
TECHNICAL DETAIL



Max Power Loading - 150W/m2 or 200W/m2

Diameter - 3.0mm - 4.0mm

230V supply

Twin conductor heating cable with single 3m “cold tail” connection lead


Ecofloor underfloor heating mat


Product Codes

Mat referenceArea to be heatedWattageWidth (m)Length (m)Price ex VAT (£)
LDTS150-0.50.5m2750.51.054.40
LDTS150-1.01.0m21500.52.057.10
LDTS150-1.51.5m22250.53.068.80
LDTS150-2.02.0m23000.54.081.00
LDTS150-2.52.5m23750.55.094.60
LDTS150-3.03.0m24500.56.0103.00
LDTS150-3.53.5m25250.57.0121.00
LDTS150-4.04.0m26000.58.0138.10
LDTS150-4.54.5m26750.59.0150.00
LDTS150-5.05.0m27500.510.0162.00
LDTS150-6.06.0m29000.512.0189.00
LDTS150-7.07.0m210500.514.0191.00
LDTS150-8.08.0m212000.5
16.0223.00
LDTS150-9.09.0m213500.518.0279.50
LDTS150-10.010.0m215000.520.0298.10
LDTS150-11.011.0m216500.522.0352.70
LDTS150-12.012.0m218000.524.0379.10
LDTS150-14.0
14.0m2
2100
0.5
28.0
418.00
LDTS150-16.0
16.0m2
2400
0.5
32.0
457.50
LDTS200-1.01.0m22000.52.059.72
LDTS200-1.51.5m2300
0.5
3.0
79.86
LDTS200-2.02.0m24000.54.0100.00
LDTS200-2.5
2.5m2
500
0.5
5.0
118.54
LDTS200-3.03.0m26000.56.0137.08
LDTS200-3.53.5m2
700
0.5
7.0
152.75
LDTS200-4.04.0m28000.58.0168.42
LDTS200-4.54.5m2900
0.5
9.0
187.94
LDTS200-5.05.0m210000.510.0207.46
LDTS200-6.06.0m212000.512.0224.48
LDTS200-7.07.0m214000.514.0254.00
LDTS200-8.08.0m216000.516.0278.98
LDTS200-9.09.0m218000.518.0305.66
LDTS200-10.010.0m220000.520.0390.98


ACCESSORIES
Product codeDescriptionPrice ex VAT (£)
TB066mm Insulated Tile Backer Board (600 x 1200mm)16.40
TB1010mm Insulated Backer Board (600 x 1200mm)16.40
ET16WWhite Touch Screen Thermostat (16A)85.00
ET16SSilver Touch Screen Thermostat (16A)88.00
ET16BBlack Touch Screen Thermostat (16A)88.00
TH232Digital Programmable Thermostat (15A)68.00
TH131Manual Analogue Thermostat (15A)50.00
Repair KitUniversal Cable Repair Kit15.00


EcoFloor Installation Video

Floor Construction


   SUSPENDED FLOORS
electric underfloor heating on a timber subfloor
When fitting ECOFLOOR electric underfloor heating mats to a timber sub-floor it is essential that standard precautions to stabilise the floor are taken to prevent floor movement. All chipboard & timber floorboards must be covered with either ECOMAX insulated tile backer board or 18mm Plywood.

TOP LAYER - Tile / Stone floor
SECOND LAYER - Tile Adhesive / Self leveling compound
THIRD LAYER - ECOFLOOR Cable Mat
FOURTH LAYER - ECOMAX Thermal Insulation
FIFTH LAYER - Suspended Timber Floor

   CONCRETE FLOORS

 electric underfloor heating on a concrete sub-floor

For optimal performance it is recommended before laying ECOFLOOR, a layer of ECOMAX insulated tile backer board is fitted. This will minimise heat losses and ensure quicker heat-up times for the floor. ECOFLOOR electric underfloor heating mats can be laid directly onto an un-insulated floor. However, this will increase running costs and heat-up times.

TOP LAYER - Tile / Stone floor
SECOND LAYER - Tile Adhesive / Self leveling compound
THIRD LAYER - ECOFLOOR Cable Mat
FOURTH LAYER - ECOMAX Thermal Insulation
FIFTH LAYER - Concrete Sub Floor

By browsing our site you agree to our use of cookies. You will only see this message once.